Follow these steps when using latex materials only. If using materials that are oil-based, follow the Cleanup and Long-
Term Storage steps.
Shutdown
1. Perform Pressure Relief Procedure, page 5. Unplug the
sprayer.
2. Turn the PRIME/SPRAY knob to PRIME. Switch the pump
OFF
(O).
3. Pour 1/2 cup water slowly on the top of the paint to prevent
the paint from drying. Wrap the spray gun assembly in a
damp cloth and place it in a plastic bag. Seal the bag shut.
Place the sprayer in a safe place out of the sun for short-
term storage.
1. Remove the gun from the plastic bag. Stir the water into
the paint.
2. Turn the PRIME/SPRAY knob to PRIME. Plug sprayer in.
Turn the switch to ON
(I).
3. Turn the PRIME/SPRAY knob to SPRAY. Test the
sprayer on a practice piece and begin spraying.
Startup
Short Term Storage (up to 16 hours)
Long-Term Storage
1. Remove the inlet filter (a).
You may need to use a
screwdriver to pry it loose.
2. Pour approximately two
ounces of light household
oil into the inlet valve
(b).
3. Remove hose from outlet
valve, place a rag over the
outlet valve, and turn the
switch ON (l). Let the unit
run for five seconds.
4. Turn the pump OFF (O)
5. Replace the inlet filter and
push the tab on the filter
(c).
6. Wipe entire unit, hose and
gun with a damp cloth to
remove accumulated paint.
Replace the spray hose.
(a)
(b)
(c)