5.4.4 CHANGING FROM ROUND JET NOZZLE TO FLAT JET NOZZLE
Perform steps 1 and 7 of paragraph 5.4.3
8. Place at jet nozzle (E) into air cap (F).
Place booth of them onto the sleeve
(G)
9. Screw nozzle nut (H) on the gun body
(K). Adjust desired jet level by means of
air cap horns (L). Tighten air cap nut (F)
by hand on the gun body (K)
Round jet nozzle
Flat jet nozzle
5.4.5 FITTING OR CHANGING FLAT JET NOZZLE
Perform steps 1 and 5 of paragraph 5.4.3
6. Unscrew nozzle nut (H) by hand.
7. Remove air cap (F) and fl at jet nozzle (E)
8. Mounting:
According to steps 8 and 9 of paragraph 5.4.4