WAGNER 0278712C Instruction Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
that it is parallel to the gun body.
14. Turn the motor switch to OFF.
Preparing the sprayer for long term storage
.
.
3.
4.
.
Remove the tip assembly and raise the suction set
above the cleaning solution.
Turn the motor to ON.
Turn the PRIME/SPRAY knob to SPRAY (F_).
Turn the pressure control knob clockwise to 1/2
power and allow the suction tube to run dry.
Remove the large suction tube from the inlet valve
and point the gun into the cleaning bucket.
.
Unlock the gun and trigger it into the cleaning
bucket until the hose is pumped dry.
7. Lock the gun and turn the pressure control knob
counterclockwise to its lowest setting.
8. Turn the PRIME/SPRAY knob to PRIME (O).
9. Lay the sprayer back on its handle so that the inlet
valve is facing upward.
10. Clean the threads of the inlet valve with a damp
cloth.
11.
Fill the inlet valve with a light household oil. Slowly
increase the pressure to distribute the oil through
the pump.
12. Turn the PRIME/SPRAY knob to SPRAY (p_) to
distribute the oil.
13. Replace the large suction tube onto the inlet valve.
NOTE: Proper cleaning and oiling of the pump after
use are the most important steps you can
take to insure proper operation after storage.
14. Turn the pressure control knob counterclockwise to
its lowest setting.
15. Turn the PRIME/SPRAY knob to PRIME (O).
16. Trigger the gun to remove any pressure which may
still be in the hose.
17.
18.
19.
Lock the gun by turning the gun safety switch so
that it is parallel to the gun body.
Turn the motor switch to OFF.
Remove and clean the suction set filter in clean
water or the appropriate solvent. Use a soft brush.
Return the suction set filter to its original position.
\
20. Wipe the entire unit, hose and gun with a damp
cloth to remove accumulated paint.
MAINTENANCE
Follow these procedures when encountering problems
indicated in the troubleshooting section.
Removing and cleaning the inlet valves
1. Be certain that the sprayer is off.
2. Remove the inlet valve assembly using a 27 millime-
ter socket or box end wrench.
.
Test movement of the valve by pushing on it from
the open end of the valve housing with a screw=
driver or the eraser end of a pencil. It should move
about 1/16 of an inch. If it does not move, it should
be cleaned or replaced.
© 1995 Wagner Spray Tech 14 All rights reserved.
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 20

Comments to this Manuals

No comments